logo
Maison > produits >
Localisateur de défaut de câble
>
35kV Cable Fault Locator and Cable Sheath Fault Detector for Outer Sleeve Failure

35kV Cable Fault Locator and Cable Sheath Fault Detector for Outer Sleeve Failure

Détails de produit:
Lieu d'origine: Xi'an Shaanxi
Nom de marque: XZH TEST
Certification: ISO CE
Numéro de modèle: XHHG520
Les informations détaillées
Lieu d'origine:
Xi'an Shaanxi
Nom de marque:
XZH TEST
Certification:
ISO CE
Numéro de modèle:
XHHG520
Mettre en évidence:

High Light

Mettre en évidence:

Outer Sleeve Failure Cable Fault Locator

,

Cable Sheath Fault Detector

,

35kV Cable Fault Locator

Trading Information
Quantité de commande min:
1 ensemble
Détails d'emballage:
Emballage en bois
Délai de livraison:
5-8 jours ouvrables
Conditions de paiement:
T/T
Capacité d'approvisionnement:
3000unité/an
Description de produit
XHHG520
The Cable Fault Locator is designed for precise detection of outer sleeve failures in cables, providing accurate fault location to minimize downtime and maintenance costs.
The equipment uses an electric voltage regulator and an R-type transformer to form a high-voltage constant current source, with keypad operation for voltage increase and decrease. The open-circuit voltage is 15kV, and the short-circuit current is 100mA. A high-sensitivity amplifier and galvanometer indicate balance, forming a balanced bridge with a proportional potentiometer, and the entire unit is positioned at a high potential. The measuring cable is a specially designed double-core high-voltage rubber cable, and a four-terminal resistance measurement method is used to avoid errors introduced by lead resistance. The entire panel is positioned at a low potential. One-button operation allows for automatic calculation of the cable length and fault distance. The high-voltage source and bridge are integrated into a portable protective case. Therefore, this equipment features high voltage, light weight, convenient operation, and safe use.
Key Features
  • Accurate detection of outer sleeve failures
  • Precise fault location capabilities
  • Designed for efficient cable maintenance
  • Reduces system downtime and repair costs
Technical Specifications
Bridge Section Open-circuit voltage  ≥15kV

Short-circuit current  ≥100mA (recommended setting: 5~40mA during balancing)

Positioning ratio  accuracy ±(0.2%·L±1) meters
Voltage and Positioning Section Input voltage 220V (±10%), 50Hz (±2Hz)

Output voltage 0~15kV (square wave) adjustable

Output current 0~200mA

Output capacity 2kVA