logo
Maison > produits >
Testeur d'hypotension ac dc
>
Intelligent Dielectric Loss Tester Automatic Measurement Fast Test Speed with Data Storage & Export Function

Intelligent Dielectric Loss Tester Automatic Measurement Fast Test Speed with Data Storage & Export Function

Détails de produit:
Lieu d'origine: Xi'an, Shaanxi, Chine
Nom de marque: XZH TEST
Certification: ISO,CE
Numéro de modèle: Le XHJS1000R
Les informations détaillées
Lieu d'origine:
Xi'an, Shaanxi, Chine
Nom de marque:
XZH TEST
Certification:
ISO,CE
Numéro de modèle:
Le XHJS1000R
Alimentation de travail:
AC 220 V ± 10 %, l'alimentation du générateur est prise en charge
Environnement opérationnel:
-15 ℃ ~ 40 ℃ Rh < 80 %
SORTIE À HAUTE TENSION:
0,5KV~10KV/200mA ±2%
Mettre en évidence:

High Light

Mettre en évidence:

Intelligent dielectric loss tester with data storage

,

Automatic measurement hipot tester fast speed

,

AC DC dielectric tester with export function

Trading Information
Quantité de commande min:
1 unité
Prix:
Négociable
Détails d'emballage:
emballage en bois
Délai de livraison:
5-8 jours ouvrables
Conditions de paiement:
T/T
Capacité d'approvisionnement:
2000unités / an
Description de produit

Product Overview

XHJS1000R Dielectric Loss Tester adopts digital notch technology to eliminate the impact of power frequency electric field on testing, overcoming the difficulty of accurate measurement under the condition of strong electric field interference. It can be powered by generators, and the configuration of oil cup and temperature control device enables the testing of insulating oil dielectric loss.

Performance Features

  • Built-in power supply, voltage booster and standard capacitor for integrated use;
  • Configure positive/reverse wiring, internal/external standard capacitors, internal/external test voltage and self-excitation method to meet diverse testing demands;
  • Achieve automatic measurement of inductance, capacitance and resistance, with angle value display;
  • Be equipped with comprehensive protection measures against input voltage fluctuation, high-voltage current, output short circuit, power supply failure, overvoltage, overcurrent, temperature deviation and other abnormal situations.

Technical Parameters

  • Measurement range: tgδ: 0~100% ±1%+0.040% Cx:15pF<Cx<300nF ±1%+1p 10kV<60nF 1kV<300nF CVT test<300nF
  • L:>20H(2kV) R>10kΩ(2kV) 0.1%
  • CVT transformation ratio: 10~10000 Accuracy: 0.1% Resolution: 0.01
  • Insulation resistance: <5% error at 100kΩ-1000GΩ(250V) 10% error at 100GΩ-1000GΩ(10000V)
  • High-voltage output: 0.5KV~10KV/200mA ±2%
  • Operating environment: -15℃~40℃ Rh<80%
  • Working power supply: AC 220V±10%, generator power supply is supported