logo
Maison > produits >
Testeur d'hypotension ac dc
>
Professional Dielectric Loss Tester for Transformer Bushing Capacitor Insulation Performance Detection

Professional Dielectric Loss Tester for Transformer Bushing Capacitor Insulation Performance Detection

Détails de produit:
Lieu d'origine: Xi'an, Shaanxi, Chine
Nom de marque: XZH TEST
Certification: ISO,CE
Numéro de modèle: Le XHJS1000R
Les informations détaillées
Lieu d'origine:
Xi'an, Shaanxi, Chine
Nom de marque:
XZH TEST
Certification:
ISO,CE
Numéro de modèle:
Le XHJS1000R
Plage de mesure : tgδ:
0~100% ±1 %+0,040 %
Cx:
15pF<Cx<300nF ±1%+1p 10kV<60nF 1kV<300nF Test CVT <300nF
L:
>20H(2kV) R>10kΩ(2kV) 0,1%
Rapport de transformation CVT:
10~10000
Résolution:
0,01
Mettre en évidence:

High Light

Mettre en évidence:

dielectric loss tester for transformers

,

transformer bushing capacitor tester

,

insulation performance tester with warranty

Trading Information
Quantité de commande min:
1 unité
Prix:
Négociable
Détails d'emballage:
emballage en bois
Délai de livraison:
5-8 jours ouvrables
Conditions de paiement:
T/T
Capacité d'approvisionnement:
2000unités / an
Description de produit
Product Overview

XHJS1000R Dielectric Loss Tester applies digital notch technology to shield the test from power frequency electric field interference, which effectively addresses the challenge of precise measurement in strong electric field interference environments. The tester is compatible with generator power supply, and when matched with an oil cup and temperature control unit, it can conduct dielectric loss testing of insulating oil.

Performance Features
  • Integrated with built-in power supply, step-up transformer and standard capacitor;
  • Support for positive/reverse connection mode, internal/external standard capacitors, internal/external test voltage and self-excitation testing method;
  • Realize fully automatic detection of inductance, capacitance and resistance, with real-time angle display function;
  • Possess multiple protective mechanisms for input voltage fluctuation, high-voltage current, output short circuit, power fault, overvoltage, overcurrent, temperature abnormality, etc.
Technical Parameters
  • Measurement range: tgδ: 0~100% ±1%+0.040% Cx:15pF<Cx<300nF ±1%+1p 10kV<60nF 1kV<300nF CVT test<300nF
  • L:>20H(2kV) R>10kΩ(2kV) 0.1%
  • CVT transformation ratio Precision: 0.1% Resolution: 0.01
  • Insulation resistance: Error below 5% at 100kΩ-1000GΩ(250V) Error of 10% at 100GΩ-1000GΩ(10000V)
  • High-voltage output: 0.5KV~10KV/200mA ±2%
  • Service conditions: -15℃~40℃ Rh<80%
  • Working power supply: AC 220V±10%, generator power supply is permissible