35kV Overhead Cable Fault Detector for Precise Overhead Line Fault Detection

35kV Overhead Cable Fault Detector for Precise Overhead Line Fault Detection

Détails de produit:
Lieu d'origine: Xi'an ShanXi Chine
Nom de marque: XZH TEST
Certification: ISO/CE
Numéro de modèle: XHJK531
Les informations détaillées
Lieu d'origine:
Xi'an ShanXi Chine
Nom de marque:
XZH TEST
Certification:
ISO/CE
Numéro de modèle:
XHJK531
Mettre en évidence:

High Light

Mettre en évidence:

35kV Overhead Cable Fault Detector

,

Overhead Line Fault Detector

,

Precise Overhead Cable Fault Detector

Trading Information
Quantité de commande min:
1 ensemble
Détails d'emballage:
Emballage en bois
Délai de livraison:
5-8 jours ouvrables
Conditions de paiement:
T/T
Capacité d'approvisionnement:
3000unité/an
Description de produit

XHJK531Overhead line fault tester

Our overhead line and cable fault detector is designed for efficient identification and location of faults in overhead power lines and cables. This essential tool helps maintenance teams quickly pinpoint issues to minimize downtime and improve system reliability.
Technical specification
Positioning accuracy 0.2 meters
Transmitter output characteristics

(1)Output frequency 1Hz

(2) Open circuit voltage: fundamental wave effective value 0~2800V,

(Pulsating DC, peak value 8kV, equivalent to the peak phase voltage of a 10kV line);

(3) Short circuit current: fundamental wave effective value 0~35mA (pulsating DC, peak value 100mA)

The wireless communication distance between the sensor and the receiver  not less than 100m
Transmitter power maximum power 900W

35kV Overhead Cable Fault Detector for Precise Overhead Line Fault Detection 0

1). Power supply: Turn on the power switch, the power indicator light is on, but there is no signal output from the transmitter at this time.

2). Start output:

 First, adjust the "Output Adjustment" knob to the zero position. The "Zero Position Indicator" light turns on. Then press the "High Pressure Close" button and slowly adjust the "Output Adjustment" knob clockwise. The "Zero Position Indicator" light goes out and the transmitter starts to output. , continue to adjust the "Output Adjustment" knob to maximize the input current, and the protection indicator light does not light up. If the protection indicator light lights up, it means that the line fault resistance is small and the input current is too large. At this time, you need to adjust the "Output Adjustment" knob counterclockwise to the zero position, and then readjust it to the appropriate position.

3). Stop output: If you need to stop output, press the "High Voltage Point" button.

4). After the work is completed, turn off the power and remove the wiring.